You will find here the information about our latest releases.
The required drivers versions for the 10.5 releases are:
- Blackmagic's drivers accepted:
- 15.0
- 15.1
- 15.2
- 15.3
- 15.3.1
Please note that the legacy auto-framing implementation has been removed due to incompatibility with semi-modern nvidia GPUs (since about 2023 without being technical).
Version 10.5.4 – 2026/10/19
FEATURES
General
- Added support for Sony BRC-AM7 camera. Camera moves go through VISCA over IP when it is enabled on the camera, and through the camera’s web API otherwise. Important: enable VISCA over IP in the camera’s menu. Without it, the camera still moves from Studio, but Pilot shows the “VISCA over IP is off on the camera” error.
- Added support for Canon CR-N350 camera.
- Improved Sony ILME-FR7 camera control: camera moves go through VISCA over IP when it is enabled on the camera, and through the camera’s web API otherwise. Important: enable VISCA over IP in the camera’s menu. Without it, the camera still moves from Studio, but Pilot shows the “VISCA over IP is off on the camera” error.
- Updated the .NET 8 runtimes to 8.0.32 to fix vulnerabilities CVE-2026-84008 and CVE-2026-70162.
Radio / Conf
- Added default continuous auto-framing tuning for Canon CR-N350 and CR-N400 cameras.
Pilot
- Added support for Sequences and Transitions on Sony BRC-AM7, Sony ILME-FR7, Canon CR-N350 and Canon CR-N400 cameras. Please note that on the ILME-FR7, zoom and focus are animated only with the FE PZ 28-135mm F4 G OSS lens; with another lens, only pan and tilt are. On the Sony cameras, Sequences and Transitions do not run while Clear Image Zoom is on or VISCA over IP is off, and Pilot shows a camera error.
BUGFIXES
General
- Fixed every command and status request to a Sony VISCA camera taking about 200 ms, whatever the camera’s response time. Preset recalls, manual moves and status updates are faster. This also applies to the Lumens and PTZOptics models controlled the same way.
- Fixed slow preset recalls and absolute moves on Sony ILME-FR7 cameras (software presets, auto-framing): pan and tilt moved at a slow fixed speed whatever the preset speed.
- Fixed automatic white balance (ATW) not being shown as automatic on Sony ILME-FR7 cameras.
- Fixed gain staying at the same value on Canon cameras such as the CR-N400 when their “Gain increment” is set to “normal”. The gain now follows the steps and the range the camera reports, including the gain limit set on its web page.
- Fixed interlaced recording not being selectable with H264 on NVIDIA T600 graphics cards, which support it (introduced in 10.5.2).
- Fixed the Solo audio mode of the current medialist item not being applied, until the next take or item change, when a source containing the medialist went on air while Multicam was starting.
Pilot
- Fixed preparing a Sequence not setting the camera’s focus mode: when the camera was in autofocus, a Sequence using a manual focus mode could start with the focus in the wrong place.
- Fixed the focus value shown for Sony ILME-FR7 cameras not following a preset recall, so that a focus near/far adjustment then started from the previous value.
- Fixed Canon pedestal sliders covering only ±50 of the camera’s ±250 range. Added the green pedestal on CR-N700, CR-N400 and CR-N350 cameras. The pedestal controls are now locked, and show LOCKED, while the camera’s active custom picture is protected.
Version 10.5.3 – 2026/10/06
FEATURES
Radio / Conf
- Added the “Ignore dead zones until the framing has settled” option to continuous auto-framing (default is disabled). Each axis (nose, ears line, zoom) keeps being corrected until it stays within a fraction of its dead zone, then its dead zone applies again. The thresholds are set per axis, 0.5 by default. Please note that the dead zone “Delay” setting is disabled while this option is on. The option also applies to continuous auto-framing started from Studio.
- Added the “Recall the preset if no face before going live” option, below “Using last reframed shot preset” (default is enabled). When no face is visible at the last auto-framed position right before going live, the AI recalls the shot’s original preset instead of putting an empty frame on air.
Pilot
- Added the reading of SPIRIT robot alerts when a robot connects or reconnects (Polyscole 1.8 or later). Errors that already existed, such as “magnetic stripe not detected” or “track sensor inverted”, are now shown immediately and stop running sequences, as when the robot sends them. Added the “lens disconnected” and “motor driver error” camera errors, and one error per axis limit (for example “Pan limit max reached”).
- Added a camera error when a SPIRIT dolly is not in Motion Control mode: “dolly in Manual mode” or “dolly in Degraded Position mode” (Polyscole 1.8 or later).
- Added a “SAVE NOT ALLOWED” warning: saving a preset or a sequence preset is refused while an axis of a SPIRIT robot is at its limit. The message lists the axes to move away from their limit, and the preset recording mode stays active so you can try again.
- Improved the joystick, camera settings and “!” (camera errors) buttons: clicking one of them again now closes the panel it opened. The joystick and camera settings buttons stay highlighted while their panel is shown.
BUGFIXES
General
- Fixed streaming going into error when the video took more than 2 seconds to reach a stable frame rate after the stream started. The allowed delay is now 5 seconds (already shipped in 10.5.2.1-hotfix-1).
- Fixed camera and streaming credentials being written in clear in the logs, which are sent with crash reports. Network camera user names and passwords, RTMP and WMV credentials, RTMP stream keys and SRT passphrases are now masked.
- Fixed records and streams being closed many times over when the application shuts down after a crash, which delayed the crash report.
- Attempted a fix for a rare crash when stopping a recording, as the end-of-recording pop-in opens.
- Fixed a SPIRIT head sometimes taking more than 10 seconds to report a recalled position as reached, although it was already in position. In Pilot, the sequence being prepared could stay not prepared.
- Fixed a selected medialist item being skipped, and the next one played instead (or nothing at the end of the list), when the selection from the API, Assist or Studio came a few milliseconds before the end of a previous item set to pause on its last frame.
- Fixed clicking Play on the current item of a medialist starting the next item instead, after coming back from another medialist while auto-take is enabled and the previous item was paused on its last frame.
- Fixed new rooms using by default a Multicam TURN server that is no longer in service, which could slow down or block WebRTC connections. New rooms now start with an empty “Turn configuration”, and rooms using that server have it removed during the upgrade. A TURN server of your own is kept.
Radio / Conf
- Fixed the custom microphone layout being reset to a grid when reopening the wizard to add microphones after the module was closed.
- Fixed unchecking “Restricted to specific angles of shots” disabling continuous auto-framing on every shot type instead of enabling it on all of them. Important: a configuration saved with this box unchecked reopens with the box checked and no shot type selected. Uncheck the box again, or select the shot types, then save.
Conf
- Fixed the connection to Audio-Technica ATDM consoles being duplicated after each network timeout, which flooded the logs.
Pilot
- Fixed a prepared sequence becoming impossible to play when a SPIRIT Control Panel was switched off or disconnected.
Titler
- Fixed a crash when an RSS feed contains an image with a relative or invalid address, for example in an <enclosure> tag.
Version 10.5.2 – 2026/08/24
FEATURES
General
- Improve the scanline selection to use when recording an interlaced output.
Radio / Conf
- Add face height difference filter (default is disabled). This helps select the correct person in a frame by removing persons visible in monitor etc… This can be adjusted by using the “Max head delta” field in the advanced auto-framing interface. Important: do not use the “unzoom” target lost option when using this filter.
BUGFIXES
General
- Fixed h264 on GPU allowing interlaced scanline for Turing and newer nVidia GPUs. They removed this ability some time ago.
- Fixed auto-start being triggered after refreshing a license.
- Switching scenes or playlists in quick succession could silently drop a playlist's video from the mixer, sometimes until a restart. Scene switches are now processed one at a time, which eliminates the problem.
Assist
- Fixed Assist window being sometime initially displayed outside of Windows’ desktop area. That may happen after changing the monitors setup (using EDID or move the monitors in Windows’ settings).
Radio / Conf
- Fixed minimum score not being applied dynamically when testing continuous auto-framing in the settings’ advanced editor.
Version 10.5.1 – 2026/07/28
FEATURES
General
- Fix missing runtime in installer; this resulted in Multicam crashing as soon as it opened under a very specific system configuration.
BUGFIXES
General
- Fix attempt for NDI inputs being listed on the Video Hub configuration UI when no SDI inputs are available. The “refresh” button should be visible too.
Comments
0 comments
Please sign in to leave a comment.